GROSSEUR DE CABLE ( DE CUIVRE ) À UTILISER SELON LA LONGUEUR APPROPRIÉE. COMPTABILISER LA LONGUEUR DU POSITIF ET DU NÉGATIF.
(EXEMPLE : 100 PIEDS DE CABLES DE MISE À LA TERRE + 100 PIEDS DE PORTE ÉLECTRODE, POUR UNE UTILISATION À 200A, IL FAUT UN FIL 1/0)

- | 100pi (30M) OU MOINS | 100FT (30M) OU MOINS | 150pi (45M) | 200pi (60M) | 250pi (70M) | 300pi (90M) | 350pi (105M) | 400pi (120M) |
AMPÉRAGE DE SOUDAGE | 10-60% FACTEUR DE MARCHE AWG (MM²) | 60-100% FACTEUR DE MARCHE AWG (MM²) | 10-100% FACTEUR DE MARCHE AWG (MM²) | |||||
100 | 4 (20) | 4 (20) | 4 (20) | 3 (30) | 2 (35) | 1 (50) | 1/0 (60) | 1/0 (60) |
150 | 3 (30) | 3 (30) | 2 (35) | 1 (50) | 1/0 (60) | 2/0 (70) | 3/0 (95) | 3/0 (95) |
200 | 3 (30) | 2 (35) | 1 (50) | 1/0 (60) | 2/0 (70) | 3/0 (95) | 4/0 (120) | 4/0 (120) |
250 | 2 (35) | 1 (50) | 1/0 (60) | 2/0 (70) | 3/0 (95) | 4/0 (120) | 2X 2/0 (2x70) | 2 CH. 2/0 (2x70) |
300 | 1 (50) | 1/0 (60) | 2/0 (70) | 3/0 (95) | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2 CH. 3/0 (2x95) |
350 | 1/0 (60) | 2/0 (70) | 3/0 (95) | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x 3/0 (2x95) | 2 CH. 4/0 (2x120) |
400 | 1/0 (60) | 2/0 (70) | 3/0 (95) | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x CH. 4/0 (2x120) | 2 CH. 4/0 (2x120) |
500 | 2/0 (70) | 3/0 (95) | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x 4/0 (2x120) | 3x 3/0 (3x95) | 3x 3/0 (3x95) |
600 | 3/0 (95) | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x 4/0 (2x120) | 3x 3/0 (3x95) | 3x 4/0 (3x120) | 3 CH. 4/0 (3x120) |
700 | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x 4/0 (2x120) | 3x 3/0 (3x95) | 3x 4/0 (3x120) | 3x 4/0 (3x120) | 4 CH. 4/0 (4x120) |
800 | 4/0 (120) | 2x 2/0 (2x70) | 2x 3/0 (2x95) | 2x 4/0 (2x120) | 3x 4/0 (3x120) | 3x 4/0 (3x120) | 4x 4/0 (4x120) | 4x 4/0 (4x120) |
* CETTE CHARTE EST UN GUIDE GÉNÉRAL ET NE PEUT CONVENIR À TOUTES LES APPLICATIONS. SI LES CABLES SURCHAUFFENT, UTILISEZ LA GROSSEUR SUIVANTE.
*EN PULSÉE SOUS 300A; UTILISEZ DU 2/0 ET DE 300A-450A, UTILISEZ DU 4/0.